We are not able to resolve this OAI Identifier to the repository landing page. If you are the repository manager for this record, please head to the Dashboard and adjust the settings.
This article describes a holistic DC link architecture design method that considers the end-application of the drive and its corresponding constraints e.g. the maximum battery ripple current for a battery-supplied inverter. Also, the levers that are available to comply with the design criteria are presented e.g. the use of interleaved carrier waves. This holistic approach will result in a feasible and performant Integrated Modular Motor Drive from an application point of view. Finally, a platform is presented that was developed for feasibility and performance assessment of various DC link architectures obtained from the holistic design approach. The platform comprises a fifteen phase integrable modular motor drive for an Axial Flux Permanent Magnet Synchronous Machine. It allows non-intrusive reconfiguration of the DC link architecture and implementation of various control strategies and interleaved PWM schemes