Signal acquisition, modeling and analysis of the pulmonary circulation system.

Abstract

by Ye Jian.Abstract in English and Chinese.Thesis (M.Phil.)--Chinese University of Hong Kong, 1993.Includes bibliographical references (leaves [140-147]).ABSTRACT --- p.iACKNOWLEDGEMENTS --- p.vLIST OF ABBREVIATIONS --- p.viTABLE OF CONTENTSChapter CHAPTER 1 --- IntroductionChapter 1.1 --- What is the EBI technique --- p.1-1Chapter 1.2 --- Applications of the EBI technique --- p.1-2Chapter 1.3 --- The electrical impedance rheopneumography-an overview --- p.1-4Chapter 1.4 --- Goal of the work --- p.1-6Chapter 1.5 --- Main contributions of the work --- p.1-9Chapter 1.6 --- Organization of the thesis --- p.1-9Chapter CHAPTER 2 --- Principles of the EBI technique and physiological background of the rheopneumogramChapter 2.1 --- Tissue impedance and origins of impedance change --- p.2-1Chapter 2.1.1 --- Impedance of living organs --- p.2-1Chapter 2.1.2 --- Origins of impedance change --- p.2-2Chapter 2.2 --- The data acquisition system (DAS) --- p.2-3Chapter 2.2.1 --- Impedance detector --- p.2-3Chapter 2.2.2 --- Constant current source and safety consideration --- p.2-4Chapter 2.2.3 --- Computer interface --- p.2-5Chapter 2.3 --- Electrode systems --- p.2-6Chapter 2.3.1 --- Two-/four-electrode systems --- p.2-6Chapter 2.3.2 --- Geselowitz lead field theory --- p.2-6Chapter 2.3.3 --- Comparisons between the two-/four-electrode systems --- p.2-7Chapter 2.4 --- The human cardiovascular system --- p.2-8Chapter 2.4.1 --- System operation --- p.2-8Chapter 2.4.2 --- Pulmonary hemodynamics --- p.2-9Chapter 2.5 --- Physiological background of EIR waveform --- p.2-12Chapter 2.6 --- EIR wave morphology and pathological factors --- p.2-13Chapter 2.6.1 --- Variations in the a-wave --- p.2-13Chapter 2.6.2 --- Variations in the Z-wave --- p.2-14Chapter 2.6.3 --- Variations in the C-wave --- p.2-14Chapter CHAPTER 3 --- THE COMPOSITION OF IMPEDANCE SIGNALChapter 3.1 --- Introduction --- p.3-1Chapter 3.1.1 --- Origins of the TIS --- p.3-1Chapter 3.1.2 --- EIR measurement and electrode position --- p.3-2Chapter 3.1.3 --- Optimal EIR measurement --- p.3-3Chapter 3.2 --- Current path in an inhomogeneous medium --- p.3-4Chapter 3.3 --- Numerical model --- p.3-5Chapter 3.3.1 --- 2D Model --- p.3-5Chapter 3.3.2 --- Tissue resistivity --- p.3-6Chapter 3.4 --- Calculation of the potential distribution --- p.3-7Chapter 3.5 --- Results --- p.3-9Chapter 3.5.1 --- Computer simulations --- p.3-9Chapter 3.5.2 --- Experimental results --- p.3-13Chapter 3.6 --- Discussions --- p.3-14Chapter 3.7 --- Conclusion --- p.3-16Chapter 3.8 --- Note on publications --- p.3-17Chapter CHAPTER 4 --- ON-LINE RESPIRATORY ARTEFACT REMOVAL VIA ADAPTIVE TECHNIQUEChapter 4.1 --- Introduction --- p.4-1Chapter 4.2 --- Analysis of the TIS --- p.4-3Chapter 4.3 --- Modified adaptive noise canceller --- p.4-7Chapter 4.3.1 --- Principle of the ANC method --- p.4-8Chapter 4.3.2 --- LMS algorithm --- p.4-8Chapter 4.3.3 --- MANC method --- p.4-9Chapter 4.3.4 --- Results --- p.4-10Chapter 4.4 --- Adaptive moving averager --- p.4-15Chapter 4.4.1 --- Modified moving averager --- p.4-15Chapter 4.4.2 --- Respiratory artefact elimination with adaptive MMA --- p.4-16Chapter 4.4.3 --- Performance of the adaptive MMA filter --- p.4-16Chapter 4.4.4 --- Results --- p.4-18Chapter 4.5 --- Adaptive FIR filter Design --- p.4-22Chapter 4.5.1 --- Introduction --- p.4-22Chapter 4.5.2 --- Adaptive FIR filter --- p.4-23Chapter 4.5.3 --- Results and discussions --- p.4-24Chapter 4.6 --- Simultaneously monitoring respiratory and pulmonary circulation- An application of TIS --- p.4-30Chapter 4.7 --- Comparisons of the proposed filter schemes --- p.4-33Chapter 4.7.1 --- Performance of the filters --- p.4-33Chapter 4.7.2 --- Computational complexity and reduced schemes --- p.4-34Chapter 4.8 --- Conclusions --- p.4-37Chapter 4.9 --- Notes on publications --- p.4-37Chapter CHAPTER 5 --- MODELING ANALYSIS OF THE RHEOPNEUMOGRAMChapter 5.1 --- Introduction --- p.5-1Chapter 5.2 --- Pulmonary circulation modeling --- p.5-2Chapter 5.3 --- Model deduction --- p.5-4Chapter 5.3.1 --- Pressure-flow in arteries and veins --- p.5-4Chapter 5.3.2 --- The two-chamber model and the EIR model --- p.5-5Chapter 5.4 --- Parameter estimation --- p.5-8Chapter 5.4.1 --- The fitting function and the parameter equations --- p.5-8Chapter 5.4.2 --- Curve fitting --- p.5-10Chapter 5.4.3 --- Solution of the parameter equations --- p.5-11Chapter 5.5 --- Study of the model parameter sensitivity --- p.5-12Chapter 5.6 --- Results --- p.5-13Chapter 5.7 --- Conclusion --- p.5-17Chapter 5.8 --- Notes on publications --- p.5-17Chapter CHAPTER 6 --- ANIMAL EXPERIMENTS AND CLINICAL OBSERVATIONSChapter 6.1 --- Introduction --- p.6-1Chapter 6.2 --- Animal experiments --- p.6-2Chapter 6.2.1 --- Methods --- p.6-2Chapter 6.2.2 --- Occlusion of the right pulmonary arterial blood flow --- p.6-3Chapter 6.2.3 --- Reflection waves in rheopneumogram --- p.6-4Chapter 6.3 --- Clinical observations --- p.6-4Chapter 6.3.1 --- Mitral valve stenosis --- p.6-5Chapter 6.3.2 --- Obstructive emphysema --- p.6-7Chapter 6.4 --- Conclusion remarks --- p.6-8Chapter 6.5 --- Notes on publications --- p.6-9Chapter CHAPTER 7 --- RECAPITULATION AND TOPICS FOR FUTURE INVESTIGATIONChapter 7.1 --- Recapitulation --- p.7-1Chapter 7.2 --- Conclusions --- p.7-3Chapter 7.3 --- Topics for future investigation --- p.7-4Chapter 7.4 --- Applications of the EIR technique --- p.7-5REFERENCESAPPENDICESChapter A. --- A circuit diagram of the four-electrode system --- p.A-lChapter B. --- NISA/EMAG (A SOFTWARE PACKAGE OF FEM) --- p.A-2Chapter C. --- LMS algorithm --- p.A-3Chapter D. --- Curve fitting --- p.A-5Chapter E. --- List of publications --- p.A-

Similar works

This paper was published in CUHK Digital Repository.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.