Voxel-based partial volume correction for accurate quantitative voxel values

Abstract

Purpose: The accuracy of voxelized information in emission imaging is limited by spatial resolution (FWHM = 2.35σ) producing biases for objects smaller than 3 FWHM. If the signal distribution is non‐uniform within 3σ of the voxel of interest then equilibrium does not exist and partial volume effect (PVE) compromises voxel accuracy. We propose a mathematical model to improve the accuracy of quantitative images of arbitrary distribution by bounding true voxel signal and estimating PVE for each voxel.Methods: A monotonically increasing parametric dataset is created for each voxel of an emission image by radial integration from the voxel center to radius = 6σ. Each cumulative integration plot from r = 3σ to 6σ is fit to a function A*4π /3*r3 + B*ΔV derived assuming a local uniform signal distribution (A) where ΔV is the voxel volume. The constant BΔV represents the converged within 3σ integral of PVE. B &gt; 0 implies spill‐out, B &lt; 0 spill‐in, and B = 0 no PVE. We tested the proposed model on simulations of 1D&amp;2D datasets containing known signal distributions and 18F‐PET/CT images of a 6cc lung lesion and bladder.Results: Signal accuracy was &gt; 99% in simulated 1D &amp; 2D datasets. For the tumor, the original maximum value was 10kBq/ml. We obtained A = 3.5kBq/ml and B = 14kBq/ml for a total of 17.7kBq/ml. This yields (A+B)/original = 1.8 indicating substantial spill‐out of ~80% and a large error for the original voxel value. For a voxel in the center of the bladder, the original value was 46kBq/ml with A = 44kBq/ml, B = 7kBq/ml. (A+B)/original = 1.11 indicating near‐equilibrium at center of bladder and low spill-out of ~11% as expected. Local signal images (A) resemble low‐pass filtered original image and (B) shows the magnitude and direction of PVE. Conclusion: A new mathematical model to estimate the accuracy of voxels in quantitative images of arbitrary distribution has been developed. Analysis of additional patients is underway.-------------------------------------Cite this article as: Mikell J, Kappadath SC. Voxel-based partial volume correction for accurate quantitative voxel values. Int J Cancer Ther Oncol 2014; 2(2):020229. DOI: 10.14319/ijcto.0202.29</p

Similar works

This paper was published in Directory of Open Access Journals.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.