Repository landing page

We are not able to resolve this OAI Identifier to the repository landing page. If you are the repository manager for this record, please head to the Dashboard and adjust the settings.

A multi finger electromagnetic actuator apparatus for biomechanical studies on the hand

Abstract

Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2005.Includes bibliographical references (leaves 77-80).The focus of this thesis was on the design and construction of a multi-finger haptic device powered by electromechanical voice-coil actuators. Five actuators were designed and constructed and a position and force feedback control system was implemented for each. The maximum continuous force output for each actuator ranged from 12-16 N, which is about 15%-30% of the maximum force that can be exerted by an individual finger. The bandwidth of the controlled actuators ranged from 0.7 Hz to 1.7 Hz, the steady-state error was zero, and the overshoot ranged from 3.5% to 7.7%. Four actuators were constructed into an array, with finger contact points 23 mm apart. Additional structures, such as finger holders and a wrist rest, were developed to complete the human interface. With further modifications, the multi-finger apparatus can be used to conduct biomechanical and perceptual studies of the human hand.by Kathleen L. DobsonS.M

Similar works

This paper was published in DSpace@MIT.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.