Validity of a contact mat and accelerometric system to assess countermovement jump from flight time

Abstract

Countermovement jump (CMJ) height is an important parameter in physical performance. This study compared CMJ height measured using ChronoJump contact mat (CJ) and Myotest accelerometer (MT) systems with a force platform (FP). Thirty recreationally active adults (32.1 ± 10.4 years, 75.9 ± 12.0 kg, 173.2 ± 6.3 cm) completed a CMJ protocol where height was simultaneously recorded using the three systems. CJ and MT measures were strongly and significant correlated (r = 0.65, 0.66, respectively; p 0.05), yet MT-derived measures were significantly different from those obtained using the FP (p < 0.05). Systematic bias was observed between FP and the CJ and between FP and MT. This study demonstrates the validity of CJ and MT systems for the assessment of CMJ height. Systematic bias and between-device differences in measurement should be considered when interpreting and comparing data from these devices

Similar works

Full text

thumbnail-image

aCQUIRe

redirect
Last time updated on 20/10/2022