An open-phase fault detection method for six-phase induction motor drives

Abstract

Malaga (Spain), 4th to 6th April, 2017 Comunicaciones del Congreso Publicadas en: Renewable Energy and Power Quality Journal (RE&PQJ) ISSN 2172 038X, No.15 April 2017Induction machines (IM) with multiple sets of three-phase windings are a real alternative in safety- critical applications due to their inherent redundancy and extra number of freedom degrees. These properties can be used to devel op a fault-tolerant system without extra hardware. The fault detection is mandatory in the creation of a fault tolerant system. Since, the fault localization allows to adapt the control scheme of this anomalous mode of operation. Nowadays, open-phase faults (OPFs) and six-phase IMs are hot topics in the literature of fault-tolerant drives. Thus, this paper presents an open-phase fault detection method for a six-phase IM drive . The detection method is based o n the vector space decomposition (VSD), taking the components of the secondary orthogonal subspace to localize the open-phase fault. The goodness of the proposed method is validated with simulation resultsMinisterio de Ciencia e Innovacion ENE2014-52536-C2–1-