Repository landing page

We are not able to resolve this OAI Identifier to the repository landing page. If you are the repository manager for this record, please head to the Dashboard and adjust the settings.

The Performance Analysis of a Three-Phase Grid-Tied Photovoltaic System in a Tropical Area

Abstract

This paper describes the performance of a three-phase grid-tied 30.05kWp photovoltaic (PV) system on the rooftop of a high rise building in Singapore. The PV system consists of an array of 15.05kWp Mono-crystalline panels and another of 15kWp Poly-crystalline panels. They are arranged in 6 strings and are set up on the same roof top. This paper looks into the performance ratio and the capacity utilization factor CUF) over a 4 month period from March 2010 to June 2010. The PV system has achieved a high performance ratio of 81.8%. The remaining 18.2% of the incident solar energy in the analysis period that is not converted into usable energy can be attributed to factors such as pre-photovoltaic losses, module and thermal losses along the balance of system (BOS) and system losses. The CUF is calculated to be 15.32%. This paper discusses the PV system installation and the considerations taken during the design and installation phase such that a high performance ratio is achieved

Similar works

Full text

thumbnail-image

GSTF Digital Library (GSTF-DL): Open Journal Systems (Global Science and Technology Forum)

redirect
Last time updated on 29/10/2019

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.