Repository landing page

We are not able to resolve this OAI Identifier to the repository landing page. If you are the repository manager for this record, please head to the Dashboard and adjust the settings.

Integrated Quality Control of Precision Assemblies using Computed Tomography

Abstract

Røntgen computer-tomografi (CT) bringer en grundlæggende ændring i den måde toleranceverifikation udføres i industrien. CT tillader måling af de indre og ydre geometrier af et emne, uden behov for ekstern tilgang eller destruktive forsøg. Dette er betydelige fordele i forhold til koordinatmålemaskiner (KMM), når der arbejdes med komplekse og skrøbelige emner. Dette ph.d. projekt ved DTU Mekanik omhandler anvendeligheden af CT for kvalitetskontrol af præcisionssamlinger. Herunder undersøgelser for at kvantificere nøjagtigheden af CT-målinger, referenceemner for at etablere måleteknisk sporbarhed af målin-ger og en international sammenligning af CT-systemer er blevet gennemført i løbet af projektet. En række undersøgelser omhandlende influenceparametre ved CT-databehandling er udført for at un-dersøge deres indflydelse på nøjagtigheden af CT-målingerne. Influenceparametre som overfladebe-stemmelse, datafiltrering og element tilpasning er gennemgået i undersøgelserne. Undersøgelserne er udført med to CT-systemer med forskellige metrologisk karakteristika og med brug af multimateriale-samlinger med forskellige geometrier og materialer. Forsøgsresultaterne viste, at CT-målinger på samlinger med succes kan udføres, og overfladebestemmelsesmetoden kan segmentere multimaterielle em-ner uden tab af nøjagtighed. Et nyt referenceobjekt for CT er udviklet i dette projekt. En type artefakt anvender en rørformet kulfiber struktur, hvorpå et antal rubinsfærer er limet på som referencer. En anden type omfatter plader af Invar, hvorpå rubinsfærer er positioneret ved forskellige højder med kulfiberstænger. Referenceobjektet er positioneret og scannet sammen med arbejdsemnet i CT-scanneren til at etablere et 3D-referencesystem til målingerne. Etablering af sporbarhed for alle objekter er udført ved hjælp af koordinatmålemaskiner med en kendt usikkerhed. De udviklede artefakter medfører en markant mindskning af tiden ved at komprimere processerne for kalibrering, scanning, måling samt re-kalibrering til et enkelt trin. Disse objekter reducerer også mængden af data genereret ved en CT-scanning. En industriel audit af CT-systemer blev udført i løbet af dette projekt. Sammenligningen involverede 22 laboratorier fra 7 lande, hvor to samlinger er blevet brugt. I forhold til tidligere sammenligninger, hvor der kun er blevet fokuseret på fysiske emner, er der i den nuværende sammenligning introduceret et voxel-emne, som er en samling scannet af koordinatoren og distribueret til deltagerne. Sammenlig-ningen har vist, at (i) længdemålinger foretages uden problemer af de fleste af deltagerne; (ii) CT-databehandling har en nævneværdig indflydelse ved komplekse måleopgaver; (iii) størstedelen af delta-gerne angav måleusikkerhed selv om mange af dem leverede ringe usikkerhedsestimater.Computed Tomography (CT) is bringing about a profound change in the way that tolerance verification is performed in industry. CT allows the inner and the outer geometry of a workpiece to be measured without the need for external access or destructive testing. These are significant advantages over coor-dinate measuring machines (CMMs) when working with complex and fragile parts. This Ph.D. project at DTU Mechanical Engineering concerns the applicability of CT for quality control of precision assem-blies. Investigations to quantify the accuracy of CT measurements, reference artefacts to correct sys-tematic errors in CT, and an international comparison on CT of Assemblies have been carried out during the project. A series of investigations regarding the influence of the CT post-processing factors on the accuracy of CT measurements was carried out. Post-processing factors such as surface determination, data filtering and feature fitting were considered within the present investigations. The investigations were conducted on two CT systems, showing different metrological performances, and involved a variety of multi-ma-terial assemblies, having different shapes and materials. The investigation results have showed that CT measurements on assemblies can be successfully conducted and that the surface determination method appears to be able to segment multi-material workpieces without any loss of accuracy. A novel type of artefact for calibration of the scale error in CT has been developed within the project. One kind of artefact comprises a carbon fibre tubular structure on which a number of reference ruby spheres are glued. Another kind comprises an invar disc on which several reference ruby spheres are positioned at different heights using carbon fibre rods. The artefact is positioned and scanned together with the workpiece inside the CT scanner producing a 3D reference system for the measurement. The two artefacts were calibrated on a tactile CMM and their applicability demonstrated using different cal-ibrated workpieces. The use of the developed artefacts ensures a considerable reduction of time by com-pressing the full process of calibration, scanning, measurement, and re-calibration, into a single imaging. The use of the artefacts also allows a considerable reduction of the amount of data generated from CT scanning. Interlaboratory comparison on Computed Tomography of assemblies was carried out as a part of the Ph.D. study. The comparison involved 22 research laboratories from 7 countries, and was based on the circulation of two assemblies. With respect to previous comparisons that only focused on physical items, the present comparison introduced a voxel item, which was an assembly scanned by the coordinator and distributed electronically to participants. The comparison results demonstrated that (i) length measure-ments are made without problems by most of the participants who corrected systematic errors effec-tively; (ii) CT post-processing has a sizable impact as the measurand complexity increases; (iii) the majority of the participants stated measurement uncertainties although many of them provided poor statements

Similar works

This paper was published in Online Research Database In Technology.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.