Repository landing page

We are not able to resolve this OAI Identifier to the repository landing page. If you are the repository manager for this record, please head to the Dashboard and adjust the settings.

Review of test methods used for the measurement of hermeticity in packages containing small cavities

Abstract

This paper presents a critical review of the traditional and newly proposed test methods used for the measurement of hermeticity in packages with very small cavity volumes. Closed-form expressions of the minimum and maximum true leak rates achievable are provided for the helium fine leak test method. These expressions are shown to provide practical guidelines for the accurate testing of hermeticity for ultrasmall packages. A portfolio of hermeticity test methods is also presented outlining the limitations and advantages of each method.</p

Similar works

This paper was published in Heriot Watt Pure.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.