Repository landing page

We are not able to resolve this OAI Identifier to the repository landing page. If you are the repository manager for this record, please head to the Dashboard and adjust the settings.

[Delta] IDDQ testing of a CMOS 12-bit charge scaling digital-to-analog converter

Abstract

This work presents design, implementation and test of a built-in current sensor (BICS) for ∆IDDQ testing of a CMOS 12-bit charge scaling digital-to-analog converter (DAC). The sensor uses power discharge method for the fault detection. The sensor operates in two modes, the test mode and the normal mode. In the test mode, the BICS is connected to the circuit under test (CUT) which is DAC and detects abnormal currents caused by manufacturing defects. In the normal mode, BICS is isolated from the CUT. The BICS is integrated with the DAC and is implemented in a 0.5 μm n-well CMOS technology. The DAC uses charge scaling method for the design and a low voltage (0 to 2.5 V) folded cascode op-amp. The built-in current sensor (BICS) has a resolution of 0.5 μA. Faults have been introduced into DAC using fault injection transistors (FITs). The method of ∆IDDQ testing has been verified both from simulation and experimental measurements

Similar works

Full text

thumbnail-image

Louisiana State University

redirect
Last time updated on 26/10/2023

This paper was published in Louisiana State University.

Having an issue?