Repository landing page

We are not able to resolve this OAI Identifier to the repository landing page. If you are the repository manager for this record, please head to the Dashboard and adjust the settings.

Towards automating underwater measurement of fish length: A comparison of semi-automatic and manual stereo-video measurements

Abstract

Underwater stereo-video systems are widely used for counting and measuring fish in aquaculture, fisheries, and conservation management. Length measurements are generated from stereo-video recordings by a software operator using a mouse to locate the head and tail of a fish in synchronized pairs of images. This data can be used to compare spatial and temporal changes in the mean length and biomass or frequency distributions of populations of fishes. Since the early 1990s stereo-video has also been used for measuring the lengths of fish in aquaculture for quota and farm management. However, the costs of the equipment, software, the time, and salary costs involved in post processing imagery manually and the subsequent delays in the availability of length information inhibit the adoption of this technology. We present a semi-automatic method for capturing stereo-video measurements to estimate the lengths of fish. We compare the time taken to make measurements of the same fish measured manually from stereo-video imagery to that measured semi-automatically. Using imagery recorded during transfers of Southern Bluefin Tuna (SBT) from tow cages to grow out cages, we demonstrate that the semi-automatic algorithm developed can obtain fork length measurements with an error of less than 1% of the true length and with at least a sixfold reduction in operator time in comparison to manual measurements. Of the 22 138 SBT recorded we were able to measure 52.6% (11 647) manually and 11.8% (2614) semi-automatically. For seven of the eight cage transfers recorded there were no statistical differences in the mean length, weight, or length frequency between manual and semi-automatic measurements. When the data were pooled across the eight cage transfers, there was no statistical difference in mean length or weight between the stereo-video-based manual and semi-automated measurements. Hence, the presented semi-automatic system can be deployed to significantly reduce the cost involved in a

Similar works

Full text

thumbnail-image

RMIT Research Repository

redirect
Last time updated on 15/12/2017

This paper was published in RMIT Research Repository.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.