Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter

Abstract

[EN] An accurate small-signal model of three-phase photovoltaic (PV) inverters with a high-order grid filter is derived in this paper. The proposed model takes into account the influence of both the inverter operating point and the PV panel characteristics on the inverter dynamic response. A sensitivity study of the control loops to variations of the dc voltage, PV panel transconductance, supplied power, and grid inductance is performed using the proposed small-signal model. Analytical and experimental results carried out on a 100-kW PV inverter are presented.Figueres Amorós, E.; Garcerá, G.; Sandia Paredes, J.; González Espín, FJ.; Calvo Rubio, J. (2009). Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter. IEEE Transactions on Industrial Electronics. 56(3):706-717. doi:10.1109/TIE.2008.201017570671756