We are not able to resolve this OAI Identifier to the repository landing page. If you are the repository manager for this record, please head to the Dashboard and adjust the settings.
[EN] An accurate small-signal model of three-phase photovoltaic (PV) inverters with a high-order grid filter is derived in this paper. The proposed model takes into account the influence of both the inverter operating point and the PV panel characteristics on the inverter dynamic response. A sensitivity study of the control loops to variations of the dc voltage, PV panel transconductance, supplied power, and grid inductance is performed using the proposed small-signal model. Analytical and experimental results carried out on a 100-kW PV inverter are presented.Figueres Amorós, E.; Garcerá, G.; Sandia Paredes, J.; González Espín, FJ.; Calvo Rubio, J. (2009). Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter. IEEE Transactions on Industrial Electronics. 56(3):706-717. doi:10.1109/TIE.2008.201017570671756
Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.